| Triumphs Only, Inc. - Triumph Technical Service Bulletin |
Distributor Contact Gap- Stag
Please note the Distributor Contact Gap clearance has been amended from 0.010" - 1.012" to 0.014"- 0.016". Consequently, the dwell angle has also changed from 34° - 37° to 29 1/2° - 33 1/2°. This new setting applies to all Triumph Stags.
The ignition timing of 11° BTCD static (5° ATCD at idle) remains unchanged.